Skip to main content
PD Industrial homepage
SEMA Racking Inspections - Because Compliance Is Non-Negotiable

SEMA Racking Inspections - Because Compliance Is Non-Negotiable

Why Racking Inspection Is Legally Required

Pallet racking is classified as work equipment under the Provision and Use of Work Equipment Regulations 1998 (PUWER). Employers have a legal duty to ensure work equipment is maintained in a safe condition and inspected where necessary to ensure it remains safe to use.

HSE guidance HSG76: Warehousing and Storage recommends a structured three-tier inspection regime: regular visual checks by users, more detailed inspections at regular intervals, and a thorough examination by a technically competent person at intervals of no more than 12 months, or more frequently where necessary.

Failure to properly manage racking safety can result in enforcement action and, where unsafe racking causes injury or a collapse, potentially serious legal and financial consequences.

SEMA Codes of Practice

SEMA's Codes of Practice provide recognised industry guidance for the safe design, installation, inspection and maintenance of pallet racking. They establish recognised standards and best-practice principles for maintaining racking safety throughout its working life.

SEMA also operates the SEMA Approved Racking Inspector (SARI) scheme, providing a recognised benchmark for the competence of professionals carrying out expert racking inspections. The SEMA inspection system uses a Red, Amber and Green (RAG) classification to help businesses identify, prioritise and address damage based on risk.

While SEMA Codes of Practice are not legislation, they provide an established industry benchmark for good practice and are referenced within HSE guidance.

See your warehouse like never before.

Discover more about our exclusive 3D scanning surveys.

Explore 3D Surveys →

What Our Inspections Cover

  • Upright frames and bracing — checking for impact damage, deformation, corrosion, and baseplate condition
  • Beams — assessing deflection, distortion, and connector pin integrity
  • Floor anchors — verifying correct specification and installation for the load being applied
  • Load notices — confirming notices are present and legible
  • Aisle clearance and safety accessories — checking column protectors, end-of-aisle barriers, and anti-collapse mesh
  • Compliance with SEMA Codes of Practice and EN 15635 standards
Warehouse aisle with pallet racking and safety barriers

The RAG Rating System

Findings are classified using the SEMA Red/Amber/Green (RAG) system

  • Red (Danger — Immediate Action Required)

    The racking must be taken out of use immediately and the load safely removed. Red-rated damage presents an imminent risk of collapse.

  • Amber (Action Required — Set Timeline)

    The damage is significant and must be repaired within a defined timeframe, determined by risk assessment. Amber-rated racking should be monitored closely until remedial action is completed.

  • Green (Acceptable — Continue to Monitor)

    Minor damage within acceptable tolerances. No immediate action required, but the item should be monitored at the next inspection.

Inspection Programmes

  • 01

    Annual Inspection

    A comprehensive annual inspection of your full racking estate, with detailed written report, RAG-rated findings, and photographic evidence. Delivered to our THEIA platform for immediate visibility.

  • 02

    Multi-Site Programme

    For operators with multiple warehouses, we coordinate a rolling annual programme ensuring every site is inspected on schedule. All findings are consolidated into THEIA for central oversight.

  • 03

    Post-Installation Inspection

    A thorough inspection following new racking installation or significant reconfiguration, confirming compliance before the system is loaded and put into use.

  • 04

    Post-Incident Inspection

    Immediate attendance following any racking impact incident, with a full structural assessment and safety sign-off before the affected area is returned to use.

Inspection findings, logged directly into THEIA.

Our platform creates a permanent, auditable record of every finding, repair, and sign-off.

Learn About THEIA →

FAQs Asked Questions

Book a Racking Inspection

Contact our team to arrange a SEMA inspection for your site or sites.

Book an Inspection →

Request a callback